Description : Measuring range pH -2.000 ... 19.999 pH
Resolution 0.1 / 0.01 pH
Accuracy electrode: ±0.02 pH
Input current ≤1×10^-12 A
Input resistance ≥3×10^12 Ω
Measurement stability ±0.01 pH/3h
Temperature compensation 0 ... 100 °C / 32 ... 212 °F (automatic / manual)
Measuring range mV -1999.9 ... 1999.9 mV
Resolution 1 mV
Accuracy ±0.03 % of measuring range
Measuring range temperature -10 ... 110 °C / 14 ... 230 °F
Resolution 0.1 °C
Accuracy 5 ... 60 °C (41 ... 140 °F): ±0.4°C
rest: ±0.8 °C
Measuring range conductivity 0 ... 19.99 µS/cm
20.0 ... 199.9 µS/cm
200 ... 1999 µS/cm
2.00 ... 19.99 mS/cm
20.0 ... 1999.9 mS/cm
Resolution 0.01 / 0.1/ 1 μS/cm, 0.01 / 0.1 mS/cm
Accuracy measuring device: ±0.5 % of measuring range
in combination with measuring electrode: ±1.0 % of measuring range
Temperature compensation 0 ... 100 °C / 32 ... 212 °F (automatic / manual)
Adjustable electrode constant 0.1 / 1 / 10 cm^-1
Adjustable reference temperature 25 °C / 77 °F, 20 °C / 68 °F, 18 °C / 64 °F
Measuring range TDS 0 ... 100 g/l
Resolution 0.001 mg/l
Accuracy measuring device: ±0.5 % of measuring range
in combination with measuring electrode: ±1.0 % of measuring range
Temperature compensation 0 ... 100 °C / 32 ... 212 °F (automatic / manual)
Adjustable electrode constant 0.1 / 1 / 10 cm^-1
Adjustable reference temperature 25 °C / 77 °F, 20 °C / 68 °F, 18 °C / 64 °F
Measuring range salinity 0 ... 100 ppt
Resolution 0.1 ppt
Accuracy measuring device: ±0.5 % of measuring range
in combination with measuring electrode: ±1.0 % of measuring range
Temperature compensation 0 ... 100 °C / 32 ... 212 °F (automatic / manual)
Adjustable electrode constant 0.1 / 1 / 10 cm^-1
Adjustable reference temperature 25 °C / 77 °F, 20 °C / 68 °F, 18 °C / 64 °F
Measuring range resistance 0 ... 100 MΩ cm
Resolution 0.001 / 0.01 / 0.1 / 1M Ω·cm
Accuracy measuring device: ±0.5 % of measuring range
in combination with measuring electrode: ±1.0 % of measuring range
Temperature compensation 0 ... 100 °C / 32 ... 212 °F (automatic / manual)
Adjustable electrode constant 0.1 / 1 / 10 cm^-1
Adjustable reference temperature 25 °C / 77 °F, 20 °C / 68 °F, 18 °C / 64 °F
Data memory 300 pH measuring points
300 conductivity measuring points
Content of a memory point date and time, measured value with unit and temperature
Display 7" touchscreen
Resolution 1024 x 600 pixels
Interfaces USB A
USB B
Bluetooth
Power supply Primary: 230 ... 240 V / 50 Hz
Secondary: 12 V DC / 1 A
Operating conditions 5 ... 35 °C / 41 ... 95 °F, < 85 % RH not condensing
IP protection class IP 54
Dimensions 175 × 220 × 40 mm / 68.9 x 86.6 x 15.7"
Weight ca. 310 g / 10.9 lb