Description : Technical specifications
Function Measurement range; Accuracy; Resolution
Measurement of real power (AC, real value of power), direct measurement 1 W ... 6 kW; 1 W; ±1.5 % + 5 dgt.
Measurement of real power (AC, real value of power), with adaptor ext. or current converter 1 W ... 999.9 kW; 1 W; ±1.5 % + 5 dgt.
Measurement of apparent power (AC) 0.01VA to 9.999kVA; 0.01VA; ±2% +2 digit
Power factor (cos φ) 0.00 to 1.00; 0.01; ±1.5% +2 digit
KWh counter 0.001Wh to 9,999kWh; 0.001Wh; ±1% +1 digit
ACV / DCV 0.1V to 600V; 0.1 / 1V; ±1% +1 digit (101 ... 600V)
ACA eff/rms
DCA eff/rms direct maximum 10A; 10mA, with induction head max. 1,000A;1A; ±1% +3 digit
ACA with clamps up to 2,000A (depending on clamps)
Frequency 10.0 to 999Hz; 0.1Hz; 1% +1 digit
Ohms 1 Ω to 19.99kΩ; 1 / 10 Ω; ±1% +1 digit
Display 93 x 52mm multi functional LCD
Operating conditions max. 80% r.h. / 0 to 50°C / 32 to 122°F
Power 6 AA batteries or mains adaptor
Dimensions 280 x 210 x 90 mm / 11 x 8.2 x 3.5 in
Weight 1,600 g / 56.4 oz
Examples of use
In the following image there is a PCE-PA 6000 being used to repair a computer. Using the current adaptor, it can quickly take measurements of consumption and measurements of power without the need to use too many cables. the PCE-PA 6000 power meter used n repairing a computer
the PCE-PA 6000 power meter with the PCE-PA-ADP current adaptor Here is an image of the power meter's large LCD that can show four different readings simultaneously. The display mode depends on the function setting.
It can also show readings taken by the current adaptor. It just needs to be connected to the device with the grounding wire of the adaptor.
In this instance, the device is being used to test the thermal value of an electronic thermal ventilator once repaired with our PCE-PA 6000 power meter. The usefulness of the current adaptor can be appreciated here, and it is easy to attach safely without the mess of external cables. With the power meter, tests can be done easily, safely and accurately an all types of small electrical appliances up to 10A, including high consumer electronics. the PCE-PA 6000 power meter used to repair small electronic devices