Power Analyzer PCE-830-2

*We may have a couple of units In Stock. Kindly drop your contact details and we will get back to you shortly.

Category :Instrumentation
Sub Category : Meters
Make :PCE
Model :Meter
Product Condition :new
Product Testing Status : Not Applicable
Type : Enquire
Availability : On Enquiry
Warranty :
Datasheet :
Description : Technical Specifications Measurement values Measurement ranges / resolution / accuracy PCE-830 + PCE-6801 Watts AC (50 Hz or 60 Hz, PF 0.5 up to 1) 5.0 W to 999.9 W / 0.1 W / ±1% ±0.8 W 1.000 kW to 9.999 kW / 0.001 kW / ±1% ±8 W 10.00 kW to 99.99 kW / 0.01 kW / ±1% ±80 W 100.0 kW to 999.9 kW / 0.1 kW / ±1% ±0.8 kW 1,000 kW to 9,999 kW / 1 kW / ±1% ±8 kW PCE-830 + PCE-6802 Watts AC (50 Hz or 60 Hz, PF 0.5 up to 1) 5.0 W to 999.9 W / 0.1 W / ±1% ±0.8 W 1.000 kW to 9.999 kW / 0.001 kW / ±1% ±8 W 10.00 kW to 99.99 kW / 0.01 kW / ±1% ±80 W 100.0 kW to 999.9 kW / 0.1 kW / ±1% ±0.8 kW 1000 kW to 9999 kW / 1 kW / ±1% ±8 kW 0.000 MW to 9.999 MW / 0.001 MW / ±1% ±80 kW PCE-830 + PCE-3007 Watts AC (50 Hz or 60 Hz, PF 0.5 up to 1) 10.0 W to 999.9 W / 0.1 W / ±1% of measurement range 1.000 kW to 9.999 kW / 0.001 kW / ±1% of measurement range 10.00 kW to 99.99 kW / 0.01 kW / ±1% of measurement range 100.0 kW to 999.9 kW / 0.1 kW / ±1% of measurement range 1,000 kW to 9,999 kW / 1 kW / ±1% of measurement range PCE-830 + PCE-6801 Current AC (50 Hz or 60 Hz, auto range select, TRMS) 0.04 A to 1 A / 0.001 A / ±0.5% ±0.05 A 0.4 A to 10.0 A / 0.01 A / ±0.5% ±0.05 A 4 A to 100.0 A / 0.1 A / ±1.0% ±0.5 A PCE-830 + PCE-6802 Current AC (50 Hz or 60 Hz, auto range select, TRMS) 10.00 A / 0.01 A / 4 A to 100.0 A / 0.01 A / ±0.5% ±0.5 A 40 A to 1000.0 A / 0.1 A / ±0.5% ±5 A PCE-830 + PCE-3007 Current AC (50 Hz or 60 Hz, auto range select, TRMS) 0 to 300 A / 0.1 A / ±1.0% of measurement range 300.0 A to 999.9 A / 0.1 A / ±1.0% of measurement range 1,000 A to 3,000 A / 1 A / ±1.0% of measurement range Voltage AC (50 Hz or 60 Hz, TRMS) 20.0 V ... 500.0 V / 0.1 V / ±0.5 % ±5 digits (grounded) 20.0 V ... 600.0 V / 0.1 V / ±0.5 % ±5 digits (phase to phase) Harmonic distortionof AC voltage 1º to 20º / 0.1% / ±1.0% 21º to 49º / 0.1% / 4% of reading ±2.0% 50º to 99º / 0.1% / 6% of reading ±2.0% PCE-830 + PCE-6801 Harmonics of AC current in % 1º to 20º / 0.1% / ±0.2% of reading ±1.0% 11º to 20º / 0.1% / ±2% of reading ±1.0% 21º to 50º (A)/ 0.1% / ±5% of reading ±1.0% 21º to 50º (mA)/ 0.1% / ±10% of reading ±1.0% 51º to 99º / 0.1% / ±35% of reading ±1.0% PCE-830 + PCE-6802 Harmonics of AC current in % 1º to 10º / 0.1% / ±2% 21º to 49º / 0.1% / 4% of reading ±2.0% 50º to 99º / 0.1% / 6% of reading ±2.0% PCE-830 + PCE-3007 Harmonics of AC current in % 1º to 10º / 0.1% / ±2% 21º to 49º / 0.1% / ±6% 50º to 99º / 0.1% / ±10% PCE-830 + PCE-6801 / PCE-830 + PCE-6802 Power Factor (PF) 0.00 to 1.00 / 0.01 / ±0.04 PCE-830 + PCE-3007 Power Factor (PF) 0.000 to 1,000 / 0.001 / ±0.04 PCE-830 + PCE-6801 / PCE-830 + PCE-6802 Phase angle (Phi) -180° to 180° / 0.1° / ±1° PCE-830 + PCE-3007 Phase angle (Phi) 0° to 180° / 0.1° / ±2° PCE-830 + PCE-6801 Total harmonic distortion 0.0 to 20.0% / 0.1% / ±1% 20.0% to 100% / 0.1% / ±3% of reading ±5% 100% to 999.9% / 0.1% / ±10% of reading ±10% PCE-830 + PCE-6802 Total harmonic distortion 0.0 to 20.0% / 0.1% / ±2% 20.0% to 100% / 0.1% / ±6% of reading ±1% 100% to 999.9% / 0.1% / ±10% of reading ±1% PCE-830 + PCE-3007 Total harmonic distortion 0.0 to 20.0% / 0.1% / ±2% 20.0% to 100% / 0.1% / ±6% of reading ±1% 100% to 999.9% / 0.1% / ±10% of reading ±1% Maximum measurement of AC voltage and current 50 Hz / 19 µS / ±5% ±30 digits 60 Hz / 16 µS / ±5% ±30 digits Peak value measurement of AC voltage and current 1.00 to 99.99 / 0.01 / ±5% ±30 digits Frequency range in automatic mode 45 Hz to 65 Hz / 0.1 H z / 0.1 Hz Memory 512 kB for a maximum 52,420 readings taken by 1 phase / 2 conductors Port USB Software and cable included, for Windows 2000, XP, ME Display backlit LCD with dot matrix Power 8 AA batteries (Mignon) Dimensions 257 mm x 155 mm x 57 mm 10.1 in x 6.10 in x 2.24 in Weight 1.16 kg / 2.56 lbs Operating conditions max. 85% relative humidity -10º C to 50º C / 14º F to 122º F Type of protection / standards IEC 61010, 600 V/CAT III Set 1: PCE-830 + PCE-6801 amp clamp (100 A) - Electrical conductor pick-up: 30 mm / 1.2 in diameter - Range selection: manual (1 A, 10 A, 100 A) - Dimensions: 210 mm x 62 mm x 36 mm / 8.2 in x 2.4 in x 1.4 in - Weight: 200 g / 7 oz Set 2: PCE-830 + PCE-6802 amp clamp (1000 A) - Electrical conductor pick-up: 55 mm / 2.2 in diameter - Range selection: manual (10 A, 100 A, 1,000 A) - Dimensions: 244 mm x 97 mm x 46 mm / 8.6 in x 97 in x 46 in - Weight: 600 g / 1.3 lbs Set 3: PCE-830 + PCE-3007 flexible amp clamp (3000 A) - Electrical conductor pick-up: 170 mm / 6.69 in diameter - Minimum radial curve : 35 mm / 1.4 in - Length of electrical conductor: 610 mm / 24.0 in - Diameter of electrical conductor: 14 mm / 0.55 in - Dimensions (Box): 130 mm x 80 mm x 43 mm / 5.1 in x 3.1 in x 1.6 in - Weight: 410 g / 14.4 oz Outline of the PCE-830 Connecting the amp clamps to the PCE-830: 1. Turn on the device. 2. Push the "1f3f" key until "3P3W" appears on the display for 3 phases / 3 conductors. 3. Connect the 3 test cables from the voltage with L1, L2, L3 and the analyser. The amp clamps are connected, as seen in the image to the right, between the device and the circuit. 4. The results can then be seen on the display.
Power Analyzer PCE-830-2
Power Analyzer PCE-830-2

Product Specifications

Power Analyzer PCE-830-2 NA
Power Analyzer PCE-830-2
Power Analyzer PCE-830-2

0 Reviews

-

Write a review

Please Login to Add Review


Related Products

Indianacart Top