Datasheet :
Description : AC voltage Measuring range Resolution Accuracy 60 mV 0.001 mV ± (0.6% 60 digits) @ 45 Hz ... 1 kHz 600 mV 0.01 mV ± (0.3% 30 digits) @ 45 Hz ... 1 kHz 6V 0.0001V ± (0.3% 30 digits) @ 45 Hz ... 1 kHz 60V 0.001V ± (0.3% 30 digits) @ 45 Hz ... 1 kHz 600V 0.01V ± (0.4% 30 digits) @ 45 Hz ... 1 kHz 1000V 0.1V ± (0.6% 30 digits) @ 45 Hz ... 1 kHz Input impedance:> 10MΩ Surge protection: 1000V Display: True RMS in the measuring range of 10 ... 100% of the respective measuring range DC voltage Measuring range Resolution Accuracy 60 mV 0.001 mV ± (0.025% + 20 digits) 600 mV 0.01 mV ± (0.025% + 5 digits) 6V 0.0001V ± (0.025% + 5 digits) 60V 0.001V ± (0.025% + 5 digits) 600V 0.01V ± (0.003% + 5 digits) 1000V 0.1V ± (0.003% + 5 digits) Input impedance:> 10MΩ Surge protection: 1000V AC voltage + DC voltage Measuring range Resolution Accuracy 60 mV 0.001 mV ± (1% + 80 digits) @ 50 Hz ... 1 kHz 600 mV 0.01 mV ± (1% + 80 digits) @ 50 Hz ... 1 kHz 6V 0.0001V ± (1% + 80 digits) @ 50 Hz ... 1 kHz 60V 0.001V ± (1% + 80 digits) @ 50 Hz ... 1 kHz 600V 0.01V ± (1% + 80 digits) @ 50 Hz ... 1 kHz 1000V 0.1V ± (1.2% + 80 digits) @ 50 Hz ... 1 kHz Input impedance:> 10MΩ Surge protection: 1000V Display: True RMS in the measuring range of 10 ... 100% of the respective measuring range Alternating current Measuring range Resolution Accuracy 600 µA 0.01 µA ± (0.6% + 40 digits) @ 45 Hz ... 1 kHz 6000 µA 0.1 µA ± (0.6% + 20 digits) @ 45 Hz ... 1 kHz 60-mA 0.001-mA ± (0.6% + 40 digits) @ 45 Hz ... 1 kHz 600-mA 0.01-mA ± (0.6% + 20 digits) @ 45 Hz ... 1 kHz 10 A 0.001 A ± (1% + 20 digits) @ 45 Hz ... 1 kHz Display: True RMS in the measuring range of 10 ... 100% of the respective measuring range Overload protection: µA and mA Measurement: Fuse F 0.6 A 1000V Ø6 x 32 mm 10 A measurement: F 11 A 1000V Ø 10 x 38 mm When measuring almost 20 A, the measurement time should not be longer than 30 seconds. After the measurement, the measuring device must rest for approx. 10 minutes. Direct current Measuring range Resolution Accuracy 600 µA 0.01 µA ± (0.8% + 20 digits) 6000 µA 0.1 µA ± (0.8% + 10 digits) 60-mA 0.001-mA ± (0.8% + 20 digits) 600-mA 0.01-mA ± (0.15% + 10 digits) 10 A 0.001 A ± (0.5% + 10 digits) Overload protection: µA and mA Measurement: Fuse F 0.6 A 1000V Ø6 x 32 mm 10 A measurement: F 11 A 1000V Ø10 x 38 mm A measurement of almost 20 A should not take longer than 30 seconds. After the measurement, the measuring device must rest for approx. 10 minutes. AC + DC Measuring range Resolution Accuracy 600 µA 0.01 µA ± (0.8% + 40 digits) @ 50 Hz ... 1 kHz 6000 µA 0.1 µA ± (0.8% + 20 digits) @ 50 Hz ... 1 kHz 60-mA 0.001-mA ± (0.8% + 40 digits) @ 50 Hz ... 1 kHz 600-mA 0.01-mA ± (0.8% + 20 digits) @ 50 Hz ... 1 kHz 10 A 0.001 A ± (1.2% + 20 digits) @ 50 Hz ... 1 kHz Display: True RMS in the measuring range of 10 ... 100% of the respective measuring range Overload protection: µA and mA Measurement: Fuse F 0.6 A 1000V Ø6 x 32 mm 10 A measurement: F 11 A 1000V Ø10 x 38 mm A measurement of almost 20 A should not take longer than 30 seconds. After the measurement, the measuring device must rest for approx. 10 minutes. Resistance Measuring range Resolution Accuracy 600 Ω 0.01Ω In REL mode: ± (0.05% + 10 digits) 6 kΩ 0.0001 kΩ ± (0.05% + 2 digits) 60 kΩ 0.001 kΩ ± (0.05% + 2 digits) 600 kΩ 0.01 kΩ ± (0.05% + 2 digits) 6 MΩ 0.0001 MΩ ± (0.3% + 10 digits) 60 MΩ 0.001 MΩ ± (2% +10 digits) Surge protection: 1000 V With a measuring range of 60 MΩ the ambient humidity should be < 50%. Conductivity Measuring range Resolution Accuracy 60 nS 0.01 nS ± (2% + 10 digits) Surge protection: 1000V The ambient humidity for the measuring range should be < 50%. Capacity measurement Measuring range Resolution Accuracy 6 nF 0.001 nF ± (3% + 10 digits) 60 nF 0.01 nF ± (2.5% + 5 digits) 600 nF 0.1 nF ± (2% + 5 digits) 6 μF 0.001 μF ± (2% + 5 digits) 60 μF 0.01 μF ± (2% + 5 digits) 600 μF 0.1 μF ± (2% + 5 digits) 6 mF 1 μF ± (5% + 5 digits) 60 mF 10 μF for reference only Surge protection: 1000 V Temperature Measuring range Resolution Accuracy -40 ... 40°C 1°C ± (2.0% + 30 digits) 40 ... 400°C 1°C ± (1.0% + 30 digits) 100 ... 1000°C 1°C ± 2.5% -40 ... 104°F 1.8°F ± (2.5% + 50 digits) 104 ... 752°F 1.8°F ± (1.5% + 50 digits) 752 ... 1832°F 1.8°F ± 2.5% Surge protection: 1000V Two-channel temperature measurement Temperature sensor: Type K only applies to the measurement of temperatures below 230°C / 446°F Frequency measurement Measuring range Resolution Accuracy 60 Hz 0.001 Hz ± (0.02% + 8 digits) 600 Hz 0.01 Hz ± (0.01% + 5 digits) 6 kHz 0.0001 kHz ± (0.01% + 5 digits) 60 kHz 0.00 1kHz ± (0.01% + 5 digits) 600 kHz 0.01 kHz ± (0.01% + 5 digits) 6 MHz 0.0001 MHz ± (0.01% + 5 digits) 60 MHz 0.00 1MHz ± (0.01% + 5 digits) Surge protection: 1000V Input amplitude: 10 Hz ... 30 MHz: 600 mV <a <30 Vrm,> 30 MHz: not specified Duty cycle Measuring range Resolution Accuracy 10 ... 90% @ 0.01% ± (1.2% + 30 digits) (10Hz ... 2kHz) Surge protection: 1000V Rise time: <1 µs, the signal is centered on the trigger level Pulse width Measuring range Resolution Accuracy 250 mS 0.001 ... 0.1 mS ± (1.2% + 30 digits) Surge protection: 1000V Rise time: < 1 µs, the signal is centered on the trigger level 10 Hz ... 200 kHz: pulse width > 2 µs The pulse range is limited by the frequency of the signal Continuity test Resolution Functional description 0.01 Ω Short circuit alarm: from < 10 Ω, alarm switches off from > 50 Ω Surge protection: 1000V Diode test 0.0001V The open circuit voltage is approx. 3V and the measurable voltage drop of the PN transition is < 3V A continuous beep indicates the short circuit of the PN junction. The typical tension of the silicon PN junction is between 0.5 ... 0.8V. Surge protection: 1000V Further specifications on accuracy can be found in the operating instructions Further specification Interface USB interface Supply voltage 100 ... 240V adjustable Environmental conditions 23°C / 73.4°F ± 5°C / 41°F, < 75% RH Dimensions 310 x 240 x 120 mm / 12.2 x 9.4 x 4.7 in Weight Approx. 3713 g / 8.2 lbs
Digital Multimeter PCE-BDM 20
Digital Multimeter PCE-BDM 20

Product Specifications

Digital Multimeter PCE-BDM 20 NA
Digital Multimeter PCE-BDM 20
Digital Multimeter PCE-BDM 20

0 Reviews

-

Write a review

Please Login to Add Review


Related Products

Indianacart Top