Current Clamp PCE-PCM 3

*We may have a couple of units In Stock. Kindly drop your contact details and we will get back to you shortly.

Category :Instrumentation
Sub Category : Meters
Make :PCE
Model :Meter
Product Condition :new
Product Testing Status : Not Applicable
Type : Enquire
Availability : On Enquiry
Warranty :
Datasheet :
Description : Ambient conditions 23°C / 73.4°F ± 5°C / 41°F, < 75% RH Measuring function Current measurement AC Measuring range Resolution Accuracy 60 A 0.01 A ± 2% + 8 Dgt 600 A 0.1 A ± 2% + 8 Dgt 1000 A 1 A ± 2% + 8 Dgt Maximum input current: 1000 A AC Frequency range: 40 .... 400 Hz Measuring function Inrush current AC Measuring range Resolution Accuracy 60 A 0.01 A For reference only 600 A 0.1 A ± 5% + 60 Dgt 1000 A 1 A ± 5% + 60 Dgt Integral time: 100 ms Measuring range: 20 ... 1000 A Frequency range: 40 .... 400 Hz Measuring function Voltage measurement DC Measuring range Resolution Accuracy 6V 0.001V ± 0.5% + 5 Dgt 60V 0.01V ± 0.5% + 5 Dgt 600V 0.1V ± 0.5% + 5 Dgt 1000V 1V ± 0.8% + 4 Dgt Input impedance: 10 MΩ Maximum input voltage: 750V AC (rms value) or 1000V DC Measuring function Voltage measurement AC Measuring range Resolution Accuracy 6V 0.001V ± 0.6% + 4 Dgt 60V 0.01V ± 0.6% + 4 Dgt 600V 0.1V ± 0.6% + 4 Dgt 1000V 1V ± 0.8% + 4 Dgt Input impedance: 10 MΩ Maximum input voltage: 750V AC (rms value) or 1000V DC Frequency range: 40 ... 400 Hz Measuring function Frequency measurement with The current measuring function Measuring range Resolution Accuracy 99.99 Hz 0.01 Hz ± 1.5% + 5 Dgt 999.9 Hz 0.1 Hz ± 1.5% + 5 Dgt Measuring range: 10 ... 1 kHz Measuring range of the input signal: > 20 AAC (rms value) The input current increases with the measuring frequency. Maximum input current: 1000 AAC (rms value) Measuring function Frequency measurement with the Voltage measurement function Measuring range Resolution Accuracy 99.99 Hz 0.01 Hz ± 1.5% + 5 Dgt 999.9 Hz 0.1 Hz ± 1.5% + 5 Dgt 9,999 kHz 0.001 kHz ± 1.5% + 5 Dgt Measuring range: 10 ... 10 kHz Measuring range of the input signal: > 1V AC (rms value) The input current increases with the measuring frequency. Maximum input voltage: 1000V AC (rms value) Measuring function Frequency measurement Measuring range Resolution Accuracy 9,999 Hz 0.001 Hz ± 0.3% + 5 Dgt 99.99 Hz 0.01 Hz ± 0.3% + 5 Dgt 9,999 kHz 0.1 Hz ± 0.3% + 5 Dgt 999.9 Hz 0.001 kHz ± 0.3% + 5 Dgt 99.99 kHz 0.01 kHz ± 0.3% + 5 Dgt 999.9 kHz 0.1 kHz ± 0.3% + 5 Dgt 9,999 MHz 0.001 MHz ± 0.3% + 5 Dgt Overvoltage protection: 1000V DC or 750V AC (rms value) Range of voltage input> 2V (as the input voltage increases, so does the frequency) Measuring function Duty cycle Measuring range Resolution Accuracy 0.1 ... 99.9% 0.1% ± 0.3% + 5 Dgt Frequency range: 10 ... 10 kHz Voltage range: 2 ... 250V AC (rms value) (The voltage increases with the frequency) Duty cycle with the Frequency range: 10 ... 1 kHz Current measurement function Input current: 20 ... 1000 AAC (rms value) Duty cycle with the Frequency range: 10 ... 1 kHz Voltage measurement function Input current: 1 ... 750V AC (rms value) Input impedance: 1MΩ Measuring function Resistivity Measuring range Resolution Accuracy 600 Ω 0.1 Ω ± 0.8% + 3 Dgt 6 kΩ 0.001 kΩ ± 0.8% + 3 Dgt 60 kΩ 0.01 kΩ ± 0.8% + 3 Dgt 600 kΩ 0.1 kΩ ± 0.8% + 3 Dgt 6 MΩ 0.001 MΩ ± 2% + 5 Dgt 60 MΩ 0.1 MΩ ± 2% + 5 Dgt Measuring voltage: approx. 0.78V Overvoltage protection: 750V DC, 1000V AC (rms value) Measuring function Continuity test Measuring range Resolution Accuracy 600 Ω 0.1 Ω - Acoustic signal at < 50 Ω Test voltage: 1.48V Overvoltage protection: 750V DC, 1000V AC (rms value) Measuring function Capacitance measurement Measuring range Resolution Accuracy 9.999 nF 0.001 nF ± 3% + 5 Dgt 99.99 n.f. 0.01 nF ± 3% + 5 Dgt 999.9 nF 0.1 nF ± 3% + 5 Dgt 9.999 μF 0.001 μF ± 3% + 5 Dgt 99.99 μF 0.01 μF ± 3% + 5 Dgt 999.9 μF 0.1 μF ± 3% + 5 Dgt 9,999mF 0.001 mF ± 3% + 5 Dgt 99.99 mF 0.01 mF ± 3% + 5 Dgt Overvoltage protection: 750V DC, 1000V AC (rms value) Measuring function Diode measurement Measuring range Resolution Accuracy 3V 0.001V - DC anode side: approx. 1-mA DC cathode side: approx. 3.2V Overvoltage protection: 750V DC, 1000V AC (rms value) Measuring function Single phase power measurement Measuring range Resolution Accuracy 3 W / VA / Var 0.01 W / VA / Var ± 3% + 5 Dgt 100 W / VA / Var 0.1 W / VA / Var ± 3% + 5 Dgt 4000 W / VA / Var 1 W / VA / Var ± 3% + 5 Dgt 10 kW / VA / var 0.01 kW / VA / Var ± 3% + 5 Dgt 100 kW / VA / var 0.1 kW / VA / Var ± 3% + 5 Dgt 750 kW / VA / var 1 kW / VA / Var ± 3% + 5 Dgt Smallest measuring current: 1-mA Smallest measuring voltage: 1V Measuring function Power factor capacitive / inductive Measuring range Resolution Accuracy 0.1 ... 1 0.001 ± 5% + 5 Dgt Smallest measuring current: 1-mA Smallest measuring voltage: 1V Measuring function Harmonics measurement Measuring range Resolution Accuracy 1 - ± 3% + 10 Dgt 2 ... 6 - ± 3.5% + 10 Dgt 7 ... 8 - ± 4.5% + 10 Dgt 9 ... 10 - ± 5% + 10 Dgt 11 ... 15 - ± 7% + 10 Dgt 16 ... 20 - ± 10% + 10 Dgt Smallest measuring current: 1-mA Smallest measuring voltage: 1V The resolution depends on the voltage measuring range General specifications Measuring range Automatically and manually adjustable Maximum voltage range 1000V DC or 750V AC Maximum working height 2000 m / 6561 ft Display LCD Maximum display 5999 Dgt. Overrange "OIL" Measuring range underflow "-OL" Measuring rate 3 Hz Automatic shutdown After 30 minutes Power supply 9V block battery Battery indicator Icon if the battery voltage is too low Temperature coefficient 0.1 x accuracy x °C / °F* Operating conditions 0 ... 40°C, 32 ... 104°F Storage conditions -10 ... 60°C, 14 ... 140°F Dimensions 238 x 92 x 50 mm / 9.4 x 3.6 x 2 in Weight About 420 g / < 1 lb (with batteries) Accuracies are given at ambient conditions of 18 ... 28°C / 65 ... 83°F. *The temperature is the difference between the temperature of the operating conditions and the current ambient temperature. Example: Is the current ambient temperature greater than the temperature of the operating conditions (50°C / 122°F (current ambient temperature)) - (40°C / 104°F (operating temperature) = 10°C / 50°F Is the current ambient temperature less than the temperature of the operating conditions (0°C (operating temperature)) - (-5°C / 23°F (current ambient temperature)) = 5°C / 41°F
Current Clamp PCE-PCM 3
Current Clamp PCE-PCM 3

Product Specifications

Current Clamp PCE-PCM 3 NA
Current Clamp PCE-PCM 3
Current Clamp PCE-PCM 3

0 Reviews

-

Write a review

Please Login to Add Review


Related Products

Indianacart Top