Current Clamp PCE-DC 50
*We may have a couple of units In Stock. Kindly drop your contact details and we will get back to you shortly.
Model :Meter
Product Condition :new
Product Testing Status :
Not Applicable
Type :
Enquire
Availability :
On Enquiry
Warranty :
Description : Current measurement DC A
Measuring range Resolution Accuracy (of rdg.)
500 μA 0.01 μA ± (1% + 6 digits)
5000 μA 0.1 μA ± (1% + 6 digits)
50 A 0.01A ± (2.5% + 5 digits)
1000 A 0.1 A ± (2.5% + 30 digits)
Current measurement AC A
Measuring range Resolution Accuracy (of rdg.)
500 μA 0.01 μA ± (1.5% + 30 digits)
5000 μA 0.1 μA ± (1.5% + 30 digits)
50 A 0.01A ± (2.5% + 30 digits)
1000 A 0.1 A ± (2.8% + 30 digits)
Note: For AC A measurements, the specification of accuracy refers to the range of 5% to 100% of the measuring range
Resistivity
Measuring range Resolution Accuracy (of rdg.)
500 Ω 0.01 ± (1% + 9 digits)
5 kΩ 0.0001 ± (1% + 5 digits)
50 kΩ 0.001 ± (1% + 5 digits)
500 kΩ 0.01 ± (1% + 5 digits)
5 MΩ 0.0001 ± (3% + 10 digits)
50 MΩ 0.001 ± (3.5% + 10 digits)
Voltage measurement DC V
Measuring range Resolution Accuracy (of rdg.)
500 mV 0.01 mV ± (0.1% + 8 digits)
5V 0.0001V ± (0.1% + 4 digits)
50V 0.001 V ± (0.1% + 4 digits)
500V 0.01V ± (0.1% + 4 digits)
600V 0.1V ± (0.5% + 4 digits)
Voltage measurement AC V (50 Hz ... 1000 Hz)
measuring range Resolution Accuracy (of rdg.)
500 mV 0.01 mV
± (0.8% + 9 digits) (at 50 Hz / 60 Hz)
5V 0.0001V ± (1% + 30 digits)
50V 0.001 V ± (1% + 30 digits)
500V 0.01V ± (1% + 30 digits)
600V 0.1V ± (1% + 30 digits)
Note: The accuracy specification for AC V measurements refers to the range of 5% to 100% of the measuring range
Capacitance measurement
Measuring range Resolution Accuracy (of rdg.)
500 nF 0.01 ± (3.5% + 40 digits)
5000 nF 0.1 ± (3.5% + 10 digits)
50 μF 0.001 ± (3.5% + 10 digits)
500 μF 0.01 ± (3.5% + 10 digits)
5mF 0.0001 ± (5% + 10 digits)
Frequency measurement
Measuring range Resolution Accuracy (of rdg.)
50 Hz 0.001 ± (0.3% + 2 digits)
500 Hz 0.01 ± (0.3% + 2 digits)
5 kHz 0.0001 ± (0.3% + 2 digits)
50 khz 0.001 ± (0.3% + 2 digits)
500 kHz 0.01 ± (0.3% + 2 digits)
5 Mhz 0.0001 ± (0.3% + 2 digits)
10 MHz 0.001 ± (0.3% + 2 digits)
Duty cycle
Measuring range Resolution Accuracy (of rdg.)
5% ... 95% 0.1
± (1% + 2 digits) (from the measured value)
Pulse width: 100 μs ... 100 ms
Frequency: 10 Hz ... 10 kHz
Temperature
Measuring range Resolution Accuracy (of rdg.)
-100°C ... 1000°C / -148 ... 1832°F 0.1 ± (1% + 2.5°C / 4.5°F)
General technical data
Conductor diameter Max. 48 mm
Display
Two lines 50,000 digits
Continuity test 50 ohms / < 50-mA
Diode test 0.3-mA / 2.8V DC
Battery indicator Battery icon when battery low
Overrange OL, if measuring range exceeded
Sample rate 2 Hz
Interface Bluetooth
Peak detection > 1 ms
Thermocouple Type K
Fuse 500-mA ceramic quick-acting
AC bandwidth (AC A / AC V) 50 Hz ... 400 Hz
AC measurement True RMS
Operating conditions 5°C ... 40°C / 41 ... 104°F, max. 80% RH at 31°C
Storage conditions -20°C ... 60°C / -4 ... 140°F, max. 80% rh
Power supply 9V block battery
Automatic shutdown After about 30 minutes
Dimensions (W x H x D) 230 x 76 x 40 mm / 9 x 3 x 1.6 in
Weight 315 g / < 1 lb
Security IEC 1010-1 (2001):
EN 61010-1 (2001)
CAT III 600V
CAT II 1000V Degree of
pollution 2