Current Clamp PCE-CM 5
*We may have a couple of units In Stock. Kindly drop your contact details and we will get back to you shortly.
Model :Meter
Product Condition :new
Product Testing Status :
Not Applicable
Type :
Enquire
Availability :
On Enquiry
Warranty :
Description : Alternating current
Measuring range Resolution Accuracy
200 A 0.1 A ± (3.0% + 3 digits)
Frequency range: 40 ... 400 Hz
Maximum input current: 200 A AC
Direct current
Measuring range Resolution Accuracy
600 µA 0.1 µA ± (1.0% + 4 digits)
1000 µA 1 µA ± (1.0% + 4 digits)
Maximum input current: 1000 µA
DC
Measuring range Resolution Accuracy
600 mV 0.1 mV ± (0.7% + 3 digits)
6V 0.001 V ± (0.7% + 3 digits)
60V 0.01 V ± (0.7% + 3 digits)
600V 0.1 V ± (0.7% + 3 digits)
Input impedance: 10 MΩ
maximum input voltage: 600V DC AC rms
AC
Measuring range Resolution Accuracy
6V 0.001V ± (0.8% + 3 digits)
60V 0.01V ± (0.8% + 3 digits)
600V 0.1V ± (0.8% + 3 digits)
Input impedance: 10 MΩ
Maximum input voltage: 600V DC AC rms
Frequency range: 40 ... 400 Hz
LowZ AC / DC
Measuring range Resolution Accuracy
600V 0.1V ± (2.0% + 3 digits)
Input impedance: 10 MΩ
Maximum input voltage: 600V DC AC rmsS
Frequency range: 40 ... 400 Hz
Resistance
Measuring range Resolution Accuracy
600 Ω 0.1 Ω ± (0.8% + 3 digits)
6 kΩ 0.001 kΩ ± (0.8% + 3 digits)
60 kΩ 0.01 kΩ ± (0.8% + 3 digits)
600 kΩ 0.1 kΩ ± (0.8% + 3 digits)
6 MΩ 0.001 MΩ ± (1.2% + 3 digits)
60 MΩ 0.1 MΩ ± (1.2% + 3 digits)
Test voltage (open circuit): 0.4V
Surge protection: 250V AC / DC rms
Continuity test
Measuring range Resolution accuracy
- 0.1 Ω -
Surge protection: 250 V AC / DC rms
Beep at <50 Ω
Diode test
Measuring range Resolution Accuracy
- 0.001V -
Surge protection: 250V AC / DC rms
Forward current: 1-mA DC
Forward voltage: 3.3V DC
Capacities
Measuring range Resolution Accuracy
99.99 nF 0.01 nF ± (4.0% + 5 digits)
999.9 nF 0.1 nF ± (4.0% + 5 digits)
9.999 µF 0.001 µF ± (4.0% + 5 digits)
99.99 µF 0.01 µF ± (4.0% + 5 digits)
999.9 µF 0.1 µF ± (4.0% + 5 digits)
9.999 mF 1 µF ± (4.0% + 5 digits)
99.99 mF 0.01 mF ± (4.0% + 5 digits)
Surge protection: 250V AC / DC rms
Temperature (thermocouple type K)
Measuring range Resolution Accuracy
-20 ... 0°C 1°C ± (3.0% + 2 digits)
1 ... 400°C 1°C ± (2.0% + 2 digits)
-4 ... 32°F 1°F ± (3.0% + 4 digits)
33 ... 752°F 1°F ± (2.0% + 4 digits)
Surge protection: 250V AC / DC rms
Frequency (with current probe)
Measuring range Resolution Accuracy
99.99 Hz 0.01 Hz
± (1.5% + 5 digits)
999.9 Hz 0.1 Hz ± (1.5% + 5 digits)
> 1 kHz 0.001 kHz for reference only
Frequency range: 10 Hz ... 1 kHz
Maximum input current: 200 A AC rms
Input range: > 60 A AC rms (if the input current increases, the frequency also increases)
Frequency (when measuring voltage)
Measuring range Resolution Accuracy
99.99 Hz 0.01 Hz ± (1.5% + 5 digits)
999.9 Hz 0.1 Hz ± (1.5% + 5 digits)
9.999 Hz 0.001 kHz ± (1.5% + 5 digits)
> 10 kHz 0.01 kHz for reference only
Frequency range: 10 Hz ... 10 kHz
Frequency (direct measurement)
Measuring range Resolution Accuracy
99.99 Hz 0.01 Hz ± (0.3% + 5 digits)
999.9 Hz 0.1 Hz ± (0.3% + 5 digits)
9.999 Hz 1 Hz ± (0.3% + 5 digits)
99.99 kHz 0.01 kHz ± (0.3% + 5 digits)
999.9 kHz 0.1 kHz ± (0.3% + 5 digits)
9.999 kHz 1 kHz ± (0.3% + 5 digits)
99.99 MHz 0.01 MHz ± (0.3% + 5 digits)
Measuring range: 10 Hz ... 60 MHz
Input impedance: 10 MΩ
Input range:> 0.2V AC rms (the input voltage increases, the frequency also increases)
Maximum input voltage: 250V AC rms
Duty cycle
Measuring range Resolution Accuracy
5 ... 95% 0.1% ± 0.3%
More specifications
Range selection Automatically and manually
Maximum working height 2000 m / 6561.7 ft
Display LCD display
Largest display value 5999
Overrange "OL" display
Measuring range underflow "-OL" display
Measuring rate 3 measurements per second
Automatic shutdown After 15 minutes of inactivity
Power supply 1 x 9V block battery
Operating conditions 0 ... 40°C / 32 ... 104°F
Storage conditions -10 ... 50°C / 14 ... 122°F
Dimensions 201 x 65 x 43 mm / 7.9 x 2.6 x 1.7 in
Weight Approx. 265 g / < 1 lb (with battery)