Description : DC
Measuring range Resolution Accuracy
4V DC 1 mV ± (1.2% of measured value + 2 digits)
40V DC 10 mV ± (1.5% of measured value + 2 digits)
400V DC 100 mV ± (1.5% of measured value + 2 digits)
600V DC 1V ± (2% of measured value + 2 digits)
Input impedance 10 MΩ
Overvoltage protection 600V DC
600V AC RMS
AC
Measuring range Resolution Accuracy
4V AC 1 mV ± (1.5% of measured value + 5 digits)
40V AC 10 mV ± (1.5% of measured value + 2 digits)
400V AC 100 mV ± (1.5% of measured value + 2 digits)
600V AC 1 V ± (2% of measured value + 2 digits)
Input impedance 10 MΩ
Overvoltage protection 600V DC
600V AC RMS
Frequency range 50 ... 400 Hz
Alternating current
Measuring range Resolution Accuracy
200 A AC 100-mA ± (3.0% of measured value + 5 digits)
Overload protection 200 A AC
Frequency range 50 ... 60 Hz
Resistance
Measuring range Resolution Accuracy
400 Ω 0.1 Ω ± (1% of measured value + 4 digits)
4 kΩ 1 Ω ± (1.5% of measured value + 4 digits)
40 kΩ 10 Ω ± (1.5% of measured value + 4 digits)
400 kΩ 100 Ω ± (1.5% of measured value + 4 digits)
4 MΩ 1 kΩ ± (2.5% of measured value + 4 digits)
40 MΩ 10 kΩ ± (3.5% of measured value + 4 digits)
Overvoltage protection 250V DC
250 AC RMS
Connection thermocouple Type K connection with adapter
Capacity
Measuring range Resolution Accuracy
4 nF 0.1 nF ± (5% of measured value + 20 digits)
40 nF 1 nF ± (3% of measured value + 5 digits)
400 nF 10 nF ± (3% of measured value + 5 digits)
4 μF 100 nF ± (3% of measured value + 5 digits)
40 μF 1 μF ± (3% of measured value + 5 digits)
100 μF 10 μF ± (3% of measured value + 10 digits)
Overvoltage protection 250V DC
250 AC RMS
Check feature Test Display
Diode test Test current: 0.5-mA
Reverse Voltage: 1.5V Forward voltage of the diode
Continuity test Open circuit Voltage 0.5V Noise when resistance <50 Ω
Overvoltage protection 250V DC
250 AC RMS
General technical specifications
Jaw Capacity About 17 mm / .7 in
Display 4000 digit LCD with backlight
Continuity test Noise when resistance <50 Ω
Test current About 0.5-mA
Open circuit voltage <2V DC
Battery indicator Battery icon when battery voltage low
Display overrange OL appears in the display
Refresh rate display 3 Hz
Temperature sensor Thermocouple type K
Input impedance 10 MΩ
Operating conditions 5 ... 40°C / 41 ... 104°F, 80% rh non-condensing
Storage conditions -20 ... 60°C / -4 ... 140°F, 80% rh non-condensing
Operating altitude <2000 m
Power supply 2 x 1.5V AAA battery
Automatic shutdown 30 minutes
Security conditions IEC1010-1 (2001)
CAT II 1000V
CAT III 600V
Pollution degree 2