Calibrator PCE-RTD 20

*We may have a couple of units In Stock. Kindly drop your contact details and we will get back to you shortly.

Category :Instrumentation
Sub Category : Meters
Make :PCE
Model :Meter
Product Condition :new
Product Testing Status : Not Applicable
Type : Enquire
Availability : On Enquiry
Warranty :
Datasheet :
Description : Measuring range Resolution Accuracy (of rdg.) Measuring parameter voltage DC V 0 ... 30V 0.001V ± 0.02% of rdg. + 2 Dgt Measuring parameter current DC mA 0 ... 24-mA 0.001-mA ± 0.02%of rdg. + 2 Dgt Measurement parameter resistance 0 ... 400 Ω 0.01 Ω ± 0.02% of rdg. + 0.01Ω Pt10 ... Pt1000 -200 ... 200°C / -328 ... 392°F Pt10 ... Pt400: 0.01°C / 0.018°F ± 0.2°C / 0.36°F 200 ... 600°C / 392 ... 1112°F Pt500 ... Pt100: 0.1°C / 0.18°F ± 0.3°C / 0.54°F 600 ... 850°C / 1112 ... 1562°F ± 0,3 °C / 0.18°F Ni100 -60 ... 180°C / -76 ... 356°F 0.01°C / 0.018°F ± 0.1°C / 0.18°F Ni120 -80 ... 260°C / - 112 ... 500°F ± 0.1°C / 0.18°F Cu10 -200 ... 260°C / -328 ... 500°F ± 0.2°C / 0.36°F *In 4-wire measuring mode, a resolution of up to 0.01 Ω in the range 0 ... 1600 Ω is possible. The specified accuracy applies to the 4-wire measuring mode. With 3-wire measurement, measurement inaccuracy increases by 1°C / 1.8°F (Pt10 / Cu10), 0.6°C / 1.08°F (Pt50 / Cu50) and 0.4°C / 0.72°F (remaining types). Simulation area Resolution Accuracy* Simulation parameter resistance 0 ... 400 Ω 0.01 Ω ± 0.02% of rdg. + 0.01Ω 400 ... 4000 Ω 0.1 Ω ± 0.02% of rdg. + 0.015Ω Simulation parameters Pt10 ... Pt1000 -200 ... 200°C / -328 ... 392°F Pt10 ... Pt400: 0.01 ± 0.15°C / 0.27°F 200 ... 600°C / 392 ... 1112°F Pt500 ... Pt100: 0.1 ± 0.25°C / 0.45°F 600 ... 850°C / 1112 ... 1562°F ± 0.15°C / 0.27°F Simulation parameter Ni100 -60 ... 180°C 0.01°C / 0.018°F ± 0.15°C / 0.27°F Simulation parameter Ni120 -80 ... 260°C 0.01°C / 0.018°F ± 0.15°C / 0.27°F Simulation parameter Cu10 -200 ... 260°C 0.01°C / 0.018°F ± 0.8°C / 1.4°F *Accuracy is valid at a current of> 0.2-mA or> 0.4-mA. Compatible RTD sensor Pt10 (385), Pt50 (385), Pt100 (385), Pt200 (385), Pt400 (385), Pt500 (385), Pt1000 (385), Pt10 (3926) Ni100 (672), Ni (618), Ni120 (672), Cu10 (427), Cu50 (427), Cu100 (427) General Specifications PCE-RTD 20 Display modes Measurement: mA / V / Ω / RTD Simulation: Ω / RTD Temperature units ° C / ° F / K Current of RTD measurement About 300 μA Maximum current simulation 3-mA (0 ... 650 Ω) I < 2V / Rsim (650 ... 4000 Ω) Maximum input voltage 30V DC Temperature coefficient <30 ppm Input impedance Voltage measurement:> 1 MΩ Current measurement: 10 Ω Response time <100 ms Refresh rate display 10 Hz Data storage Internal memory 150000 readings Interface USB 2.0 Display 2.4" TFT LCD 240 x 320 pixels LED illuminated Output voltage current loop 24V DC / 24-mA HART mA loop resistance 250 Ω ± 20% Special features Step and ramp function Automatic and manual mode √x, x2: For the measuring function Continuity test Adjustable threshold up to 100 Ω Power supply 3.7V / 2300-mAh Li-ion battery Charging time About 5 h Power adapter Input: 100 ... 240V AC / 50/60 Hz Output: 5V / 1 A DC Battery life Approx. 15 h: Simulation and measurement with low LCD illumination Approx. 8 h: Measurement with low LCD illumination Dimensions 162 x 82 x 40 mm / 6.4 x 3.2 x 1.6 in Weight About 300 g / < 1 lb Degree of protection IP20 Operating conditions Battery operation: 0 ... 55°C / 32 ... 131°F, 30 ... 90% RH Mains operation: 0 ... 45°C / 32 ... 113°F, 30 ... 90% RH Storage conditions -20 .. 60°C / -4 ... 140°F, 30 ... 90% rh non-condensing Heating time About 15 minutes
Calibrator PCE-RTD 20
Calibrator PCE-RTD 20

Product Specifications

Calibrator PCE-RTD 20 NA
Calibrator PCE-RTD 20
Calibrator PCE-RTD 20

0 Reviews

-

Write a review

Please Login to Add Review


Related Products

Indianacart Top