Description : Technical specifications
Direct voltage
Range Resolution Accuracy
Input impedance: 1 MΩ 600 V 0.1 V ± 1 % + 2 digits
Direct voltage (peak model)
Input impedance: 1 MΩ 600 V
0.0 ... 0.01 in 0.1 V
0.0 ... 0.01 in ± 1.5 % + 8 digits
0.0 ... 0.01 in
Alternating voltage
Input Impedance: 1 MΩ 600 V 0.1 V ± 1.2 % ± 5 digits
(50 ... 500 Hz)
Alternating voltage (peak model)
Input impedance: 1 MΩ 600 V 0.1 V ± 1.7 % + 10 digits
Direct current
60 A
600 A 0.01 A
0.1 A ± 2 % + 5 digits
Direct current (peak model)
600 A 0.1 A ± 2.5 % + 8 digits
Alternating current
60 A
600 A 0.01 A
0.1 A ±2 % + 5 digits (50...60 Hz)
±3 % + 5 digits (60...500 Hz)
Alternating current (peak model)
600 A 0.01 A ±2.5 % + 10 digits
Electrical resistance
1000 Ω 0.1 Ω ± 1 % + 2 digits
Continuinty check
Buzzer function
<40 Ω
General specifications
Display 4-digit LCD
maximum reading: 6200
Sampling rate 3 times/s
Power supply 2 x 1.5 V AAA batteries
Batter life 50 hours (without buzzer backlight function)
Auto Power off after 30 minutes of inactivity
Operating conditions 0.0 °C ... +40 °C / < 70 % RH
0.0 °F ... +104 °F
Storage conditions -10 °C ... +60 °C / < 80 % RH
+14 °F ... +140 °F
Maximum clamp opening Ø 25 mm / Ø 0.1 in
Dimensions 210 mm x 62 mm x 36 mm
8.26 in x 2.44 in x 1.41 in
Weight 273 g / 0.6 lbs with batteries