Description : DC voltage
Measuring range 600.0 mV DC
Resolution 0.1 mV DC
Accuracy ±(0.5 % + 8 digits)
Measuring range 6.000 V DC
Resolution 0.001 V DC
Accuracy ±(1.5 % + 5 digits)
Measuring range 60.00 V DC
Resolution 0.01 V DC
Accuracy ±(1.5 % + 5 digits)
Measuring range 600.0 V DC
Resolution 0.1 V DC
Accuracy ±(1.5 % + 5 digits)
Measuring range 1000 V DC
Resolution 1 V
Accuracy ±(1.5 % + 5 digits)
Input impedance >10 MΩ
Overvoltage protection 1000 V AC/DC
AC voltage
Measuring range 6.000 V AC
Resolution 0.001 V AC
Accuracy ±(1.5 % + 5 digits)
Measuring range 60.00 V AC
Resolution 0.01 V AC
Accuracy ±(1.5 % + 5 digits)
Measuring range 600.0 V AC
Resolution 0.1 V AC
Accuracy ±(1.5 % + 5 digits)
Measuring range 1000 V AC
Resolution 1 V AC
Accuracy ±(1.5 % + 5 digits)
Peak value (PEAK) accuracy ±10 %
Peak value (PEAK) response time 1 ms
Input impedance >10 MΩ
Overvoltage protection 1000 V AC/DC
The accuracy relates to a measuring range of 10 ... 100 %
with a sine wave.
Low pass filter (LowZ)
(50 ... 400 Hz)
Measuring range 6.000 V AC
Resolution 0.001 V AC
Accuracy ±(3.0 % + 40 digits)
Measuring range 60.00 V AC
Resolution 0.01 V AC
Accuracy ±(3.0 % + 40 digits)
Measuring range 300.0 V AC
Resolution 0.1 V
Accuracy ±(3.0 % + 40 digits)
Input impedance <300 kΩ
Overvoltage protection 1000 V AC/DC
The accuracy relates to a measuring range of 10 ... 100 %
with a sine wave.
AC with DC voltage
(50 ... 400 Hz)
Measuring range 6.000 V AC
Resolution 0.001 V AC
Accuracy ±(2.5 % + 20 digits)
Measuring range 60.00 V AC
Resolution 0.01 V AC
Accuracy ±(2.5 % + 20 digits)
Measuring range 600.0 V AC
Resolution 0.1 V AC
Accuracy ±(2.5 % + 20 digits)
Measuring range 1000 V AC
Resolution 1 V AC
Accuracy ±(2.5 % + 20 digits)
Input impedance >10 MΩ
Direct current
Measuring range 600.0 A DC
Resolution 0.1 A DC
Accuracy ±(2.5 % + 5 digits)
Measuring range 1000 A DC
Resolution 1 A DC
Accuracy ±(2.8 % + 5 digits)
Overvoltage protection 1000 A DC
Alternating current
(50 ... 60 Hz)
Measuring range 600.0 A AC
Resolution 0.1 A AC
Accuracy ±(2.5 % + 5 digits)
Measuring range 1000 A AC
Resolution 1 A AC
Accuracy ±(2.8 % + 5 digits)
Overload protection 1000 A AC/DC
Flexible clamp meter
(50 ... 400 Hz)
Measuring range 30.00 A AC
Resolution 0.01 A AC
Accuracy ±(3.0 % + 5 digits)
Measuring range 300.0 A AC
Resolution 0.1 A AC
Accuracy ±(3.0 % + 5 digits)
Measuring range 3000 A AC
Resolution 1 A AC
Accuracy ±(3.0 % + 5 digits)
Overload protection 3000 A AC/DC
The accuracy relates to a measuring range of 10 ... 100 %
with a sine wave.
Resistance
Measuring range 600.0 Ω
Resolution 0.1 Ω
Accuracy ±(1.0 % + 10 digits)
Measuring range 6.000 kΩ
Resolution 0.001 kΩ
Accuracy ±(1.5 % + 5 digits)
Measuring range 60.00 kΩ
Resolution 0.01 kΩ
Accuracy ±(1.5 % + 5 digits)
Measuring range 600.0 kΩ
Resolution 0.1 kΩ
Accuracy ±(1.5 % + 5 digits)
Measuring range 6.000 MΩ
Resolution 0.001 MΩ
Accuracy ±(2.5 % + 5 digits)
Measuring range 60.00 MΩ
Resolution 0.01 MΩ
Accuracy ±(3.5 % + 10 digits)
Overvoltage protection 1000 V AC/DC
Continuity test
Signal <50 Ω
Overvoltage protection 1000 V AC/DC
Diode test
Test current <1.5 mA
Maximum tension when open
circuit 3.3 V DC
Frequency measurement
Measuring range 9.999 Hz ... 99.99 kHz
Resolution 0.01 ... 10 Hz
Accuracy ±(1.2 % + 5 digits)
Overvoltage protection 1000 V AC/DC
Sensitivity >5 Vrms with one duty cycle
from 20 ... 80 %
Duty cycle
Measuring range 10.0 ... 90.0 %
Resolution 0.1 %
Accuracy ±(1.2 % + 8 digits)
Pulse range 40 Hz ... 10 kHz
Pulse amplitude ±5 V (0.1 ... 100 ms)
Capacity
Measuring range 60.00 nF
Resolution 0.01 nF
Accuracy ±(4.0 % + 20 digits)
Measuring range 600.0 nF
Resolution 0.1 nF
Accuracy ±(3.0 % + 8 digits)
Measuring range 6.000 µF
Resolution 0.001 µF
Accuracy ±(3.0 % + 8 digits)
Measuring range 60.00 µF
Resolution 0.01 µF
Accuracy ±(3.0 % + 8 digits)
Measuring range 600.0 µF
Resolution 0.1 µF
Accuracy ±(3.0 % + 8 digits)
Measuring range 6000 µF
Resolution 1 µF
Accuracy ±(5.0 % + 8 digits)
Measuring range 60.00 mF
Resolution 0.01 mF
Accuracy ±(5.0 % + 20 digits)
Measuring range 100.0 mF
Resolution 0.1 mF
Accuracy ±(5.0 % + 20 digits)
Overvoltage protection 1000 V AC/DC
Temperature measurement
(Thermocouple Type K)
Measuring range -40 ... 600.0 °C
Resolution 0.1 °C
Accuracy ±(1.5 % + 5 digits)
Measuring range 600 ... 1000 °C
Resolution 1 °C
Accuracy ±(1.5 % + 5 digits)
Measuring range -40 ... 600.0 °F
Resolution 0.1 °F
Accuracy ±(1.5 % + 9 digits)
Measuring range 600 ... 1800 °F
Resolution 1 °F
Accuracy ±(1.5 % + 9 digits)
Overvoltage protection 1000 V AC/DC
The accuracy refers to the measuring device without temperature probe.
Specifications refer to a stable ambient condition of ±1 °C.
If the measurement lasts for a long time, the measured value increases by 2 °C
Further specifications
Clamp opening
34 mm / 1.3"
NCV >150 V AC
Display LC colour display
Display when measuring range exceeded "OL" (overload)
Measuring rate 3 measured values per second
Interface Bluetooth
Operating conditions 5 ... 40 °C / 41 ... 104 °F
<80 % RH non-condensing at
31 °C / 87 °F linearly decreasing to 50 % RH
non-condensing at 40 °C / 104 °F
Storage conditions -20 ... 40 °C / -4 ... 140 °F <80 % RH
non-condensing
Maximum working height 2000 m / 7000 ft
Power supply 3 x 1.5 V AAA batteries
Auto power off Switched off, 15, 30, 45, 60 minutes
Dimensions 250 x 80 x 40 mm / 9.8 x 3.1 x 1.5"
Weight 365 g / 12.8 oz